top of page

Leader for the identification of material defects using the eddy current method.

Arrow Down

SERVICES

tepelny vymenik

Data collection from heat exchangers

is carried out during the overhaul, either before the installation of new heat exchangers or during overhauls. The collection is performed for the ET method on an agreed number of heat exchanger tubes with qualified personnel who are professionally trained to focus on detecting damage to the tube wall thickness. Bobbin probes are used for collection together with special probe techniques (X-probe) and rotary probes (MRPC).

room analyza

Eddy current data analysis

The analysis of different types of heat exchanger tubes and steam exchangers is performed by a specialized team of analysts who have many years of experience. The analysis itself is performed on software from ZETEC or Eddyfi. After the evaluation, a report on the status of the measured component is issued to clients, which serves as a basis for further decisions on the scope of repairs performed.

PEC

PEC inspections of pipes

is performed by testing external and internal pipes or tanks with insulation or refractory coating. This method makes it possible to identify surface degradations of the perimeter cladding material, even if the tested material is under a layer of non-conductive insulation.

Aerial top view oil and gas tank with oil refinery background at night, Business petrochem

Inspection of storage tanks

Tank inspection ensures safety and integrity by preventing accidental leaks and avoiding costly decontamination, while also providing critical data for predicting lifespan and necessary repairs. Tank inspectors offer trend information about the current state of assets and recommend measures for owners and operators to secure legal operating licenses; they can potentially negotiate lower insurance rates based on verification that the tanks are in good condition.

nater PScoat

Thermal insulation coating

it is a new nanotechnology based on microspheres and is capable of withstanding temperatures from -200 to +200 °C. It can be applied directly to hot surfaces up to +150 °C and is abrasion-resistant. Its advantage lies in its very good adhesion to various surfaces and materials. The coating's application, due to its technical properties, allows for the reflection of all radiation across its entire spectrum (TSR) at 92%. It is a full-fledged replacement for polystyrene, mineral wool, and other insulating materials.

Tools and equipment for Non-Destructive

NDT inspection 

VT a PT

Capillary testing (PT) is one of the most common methods of non-destructive testing of materials. It is suitable for detecting surface defects. The VT method is focused on determining and evaluating the condition (properties) of the surfaces of products or components with the naked eye, or with the help of special devices or equipment.

2d3bd05c-aecf-46b0-8d39-51753ff139d4%202

Welding and

locksmithing

is performed during repairs of various structures, pipes or other technological equipment or components (blinding of small diameter pipes) by qualified personnel according to standards EN ISO 9606-1 141/111/135, EN ISO 96036-2 141 and in nuclear power plants also according to a special standard NDT ASI section I. We are able to provide repairs and work performance even in a difficult environment in special work suits.

kontrolní oddelení

Administrative activities

it is provided by administrative staff, who perform mapping of existing facilities in the field, check and map the technical condition, the location of all facilities and their components in the NPP building, then the information obtained is transported in digital form for further processing.

SERVICES

ABOUT US

The technical equipment of the company allows to perform data collection and analysis activities using the ET method, welding and locksmith work, perform visual and penetration inspections in the second stage during control outages at various nuclear, thermal, steam and gas power plants, as well as petrochemical plants, engineering companies (in production, or before putting the unit into operation), even in cooperation with internal and external staff.

Bobbin probes are used for data collection together with special probe techniques (X-probe) and rotary probes (MRPC) when inspecting heat exchanger tubes.

To achieve the best possible result in the identification of corrosion and defects are for the preparation of the NDT report, the most modern technical means from world leaders in the field of NDT for ET methods are used.

ABOUT

2017

>325

>8626

28

Establishment of the company

Proven heat exchangers

km of tested pipes

Professional staff

PROJECTS

PROJECTS

CERTIFIKATY

CERTIFICATION

ISO_9001_SK.png
ISO_14001_SK.png
atestace
Oprávnění Zatist_EGS_SJS.png
Certifikat ET L3
Certifikat_NDT_PT
certifikat_JZ
Certifikat svarece
ISO_45001_SK.png
SUJB potvrzeni
certfikat_NDT_RT_L2
NDT_FM1

Insurance

Our company has liability insurance within the scope of Article II. insurance contract No. 0024205915. The insurance covers the statutory obligation of the insured to compensate the injured party specified in the insurance contract and insurance conditions, if the insured arose to compensate them in connection with the activities: Testing, measurement, analysis and control; Surface treatment and welding of metals and other materials; Manufacture of metal structures and metal products; Administrative and organizational services; Locksmithing, toolmaking listed in an extract from the Commercial Register or in connection with the relations arising from these activities and in connection with a defect in the product which was placed on the market or a defect in the work provided which becomes apparent after its handover.

Potvrzení ke smlouvě č.0024205915.png
CLIENTS

CLIENTS

Our company also participated in work in thermal power plants in the Czech Republic (managed by ČEZ, as), where we provided data collection and control activities on heat exchangers.

CONTACT

CONTACT

Registration

Registered at the Regional Court in Brno

on 29.6.2017 under the brand 100677

Contact us

Thank you for your message.

Head Office

Zatist sro

Nové Sady 988/2

Brno 602 00

IČO: 06200613

IČ DPH: CZ06200613

Contacts

Libor Všiansky

Head manager

+420 777 656 546

vsiansky@zatist.cz

Ing. Vladimíra Duníková

Quality manager

kvalita@zatist.cz

Ivan Maslák

Technical support ET

+421 911 766 123

maslak@zatist.cz

Ing. Dávid Šoltýs  

Product manager PScoat

+421 910 915 475 
pscoat@zatist.cz

 

email